PRESENTATION
TomoXpert is a platform dedicated to non-destructive testing (NDT) and associated metrology, aims to bring together the equipment and skills of different entities of the University of Bourgogne Franche-Comté (UBFC), in order to propose a structured offer, in the areas of training, research, technology transfer or industrial service. The platform provides access to both conventional NDT techniques, the most advanced NDT techniques, in particular tomography (an essential technique for many current industrial and research problems), as well as techniques related to NDT, such as the use of robotic inspection systems or automated fault recognition. Its purpose is to support industrial or university partners in research or development projects and thus generate synergies.
Research unit(s):
CONTACT US
Expertise – Profitability study
R&D project – Training
Jean-Christophe KNEIP
CO-MANAGER
Jean-Christophe.Kneip@u-bourgogne.fr
Phone : 06 32 92 23 41
Site of Chalon-sur-Saône
François HENNEBELLE
CO-MANAGER
Francois.Hennebelle@u-bourgogne.fr
Phone : 06 04 01 38 82
Site of Auxerre
CERTIFICATE
TomoXpert has been authorized since March 2023 by the COS BFC, as a “Research Platform of Bourgogne Franche-Comté".
The platform relies on the industrial and academic partners who are directly linked to it, but also very strongly on the competitiveness clusters present in the BFC (Nuclear Valley) region, or on institutional partners, such as UIMM, Robotics Valley, the CETIM, Usinerie Partners, through the “CND LAB'” University-Industry platform based in Chalon/Saône. TomoXpert is the entity representing the University of Burgundy within CND LAB'. It is supported by the COFREND “French Confederation for Non-Destructive Testing".
As part of the services managed by our partner Satt Sayens, the actions carried out are ISO 9001 v2021 certified.
- kc_data:
- a:8:{i:0;s:0:"";s:4:"mode";s:2:"kc";s:3:"css";s:0:"";s:9:"max_width";s:0:"";s:7:"classes";s:0:"";s:9:"thumbnail";s:0:"";s:9:"collapsed";s:0:"";s:9:"optimized";s:0:"";}
- kc_raw_content:
- [kc_row use_container="yes" _id="724879"][kc_column width="12/12" video_mute="no" _id="872727"][kc_spacing height="20px" _id="344352"][/kc_column][/kc_row][kc_row use_container="yes" _id="801054"][kc_column width="59.76%" _id="239336"][kc_column_text _id="573117"]
PRESENTATION
TomoXpert is a platform dedicated to non-destructive testing (NDT) and associated metrology, aims to bring together the equipment and skills of different entities of the University of Bourgogne Franche-Comté (UBFC), in order to propose a structured offer, in the areas of training, research, technology transfer or industrial service. The platform provides access to both conventional NDT techniques, the most advanced NDT techniques, in particular tomography (an essential technique for many current industrial and research problems), as well as techniques related to NDT, such as the use of robotic inspection systems or automated fault recognition. Its purpose is to support industrial or university partners in research or development projects and thus generate synergies.
Research unit(s):
- ICB
- DRIVE (EA 1859, Vehicle Engineering Research Department for the Environment), based in Auxerre/Nevers.
CONTACT US
Expertise - Profitability study
R&D project - TrainingJean-Christophe KNEIP
CO-MANAGER
Jean-Christophe.Kneip@u-bourgogne.fr
[/kc_column_text][kc_spacing height="20px" _id="852548"][kc_column_text _id="379615"]
Phone : 06 32 92 23 41
Site of Chalon-sur-SaôneFrançois HENNEBELLE
CO-MANAGER
Francois.Hennebelle@u-bourgogne.fr
[/kc_column_text][kc_spacing height="20px" _id="869058"][/kc_column][/kc_row][kc_row use_container="yes" _id="869868"][kc_column width="12/12" video_mute="no" _id="980006"][kc_spacing height="40px" _id="308007"][/kc_column][/kc_row][kc_row _id="230425"][kc_column width="5%" video_mute="no" _id="560957"][/kc_column][kc_column width="40%" video_mute="no" _id="468062"][kc_call_to_action layout="2" title="CERTIFICATE" desc="__empty__" button_show="__empty__" _id="556218" css_custom="{`kc-css`:{`any`:{`description`:{`color|.kc-cta-desc .kc-cta-text`:`#1e73be`,`text-align|.kc-cta-desc .kc-cta-text`:`center`},`button`:{`color|.kc-cta-button a`:`#000000`,`background-color|.kc-cta-button a`:`#ffffff`}}}}"][kc_spacing height="20px" _id="251828"][kc_column_text _id="640133"]
Phone : 06 04 01 38 82
Site of AuxerreTomoXpert has been authorized since March 2023 by the COS BFC, as a "Research Platform of Bourgogne Franche-Comté".
The platform relies on the industrial and academic partners who are directly linked to it, but also very strongly on the competitiveness clusters present in the BFC (Nuclear Valley) region, or on institutional partners, such as UIMM, Robotics Valley, the CETIM, Usinerie Partners, through the “CND LAB'” University-Industry platform based in Chalon/Saône. TomoXpert is the entity representing the University of Burgundy within CND LAB'. It is supported by the COFREND "French Confederation for Non-Destructive Testing".
As part of the services managed by our partner Satt Sayens, the actions carried out are ISO 9001 v2021 certified.
[/kc_column_text][/kc_column][kc_column width="10%" video_mute="no" _id="430451"][/kc_column][kc_column width="40%" video_mute="no" _id="590578"][kc_call_to_action layout="2" title="EQUIPMENTS" desc="__empty__" button_show="__empty__" _id="905156" css_custom="{`kc-css`:{`any`:{`title`:{`color|.kc-cta-desc h2`:`#1e73be`,`text-align|.kc-cta-desc h2`:`center`},`description`:{`color|.kc-cta-desc .kc-cta-text`:`#1e73be`},`button`:{`background-color|.kc-cta-button a`:`#ffffff`}}}}"][kc_spacing height="20px" _id="371165"][kc_column_text _id="104782"]{slide=Actual equipments}
ULTRASOUND inspection
- UT PA (Métalscan Multi2000-Pocket16x64 and UTPA 64 sensor / Sonatest PRISMA PA option and UTPA16 probe / Associated angle shoe)
- UT TOFD (Metalscan Miniscan TOFD / Sonatest PRISMA option TOFD / Couples UT Tofd 55°,70°)
- Immersion UT (700x700 mm EPA tank, 1/5/10 MHz sensors) and Conventional and MEP UT
- Accessories (Mechanical and wired encoders / Polar encoder Sinus Arm 3 axes RTT3, 700mm / TOFD and UT PA Steel calibration wedges / Steel-Alu DAC-V1-V2 wedges / Parts with defects (Welded wedges mapped 15- 20-25-30mm, …)Inspection by RADIOGRAPHY
- 200 kV RX tube and radiation-protected cabin
- DUERR CR35 digital scanner for IP flexible rewritable films
- Welded steel RT drive parts with calibrated defects (10 pieces)Inspection by active THERMOGRAPHY
- FLIR S60 camera, µblm, LW, 50mm lens and macro
- TELOPS M350 camera, cooled, MW, 50 mm optics
- Excitation source for active thermography: Flash or modulated system, 100W continuous fiber laser and galvanometric head for active ThIR Laser, low temperature black body.Inspection by ACOUSTIC EMISSION
- Mistras AEWIN multichannel system, 100 and 150 kHzEDDY CURRENT Inspection
- Mono and bi-frequency CF systems, with stylus probes, reflection, welding, internal, external, rotating probesNDT SIMULATION tools
CIVA 2022: complete R&D versions CIVA UT, ET, RT, and academic versions for training: UT, ET, RT
MATLAB 2022, COMSOL Multiphysics 2022, FLUX, ONSCALEOther techniques
- Interferometric profilometer, intended for geometric surface characterization
- Phantom v2012 and v9.1 fast camera
- Portable poly-articulated arm (Kreon Technologies), measuring range of 3m, with laser sheet scanner + inspection software (Polyworks).{/slide}
[/kc_column_text][kc_column_text _id="220572"]{slide=Equipment being acquired}
- RX industrial tomography system, 225keV microfocus type, for checking large and thick parts
- Large field of view non-destructive X-ray 3D microcomputing tomography system for high resolution part inspection
- System of thermal stresses by induction for the inspection of metal parts by active thermography
- Pulsed and phased array NDT systems for NDT of metal parts
- NDT systems by UT PA advanced (FMC, TFM, PWI, …){/slide}
{slide=Equipment under internal development}
- System, at reduced cost, for non-destructive testing of the internal shape of shell-type parts based on the adaptation of ultrasonic systems on a polyarticulated arm.
{/slide}
[/kc_column_text][/kc_column][kc_column width="5%" video_mute="no" _id="365220"][/kc_column][/kc_row][kc_row use_container="yes" _id="391493"][kc_column width="12/12" video_mute="no" _id="208421"][kc_spacing height="30px" _id="349991"][kc_single_image image_size="full" _id="415165" image_source="media_library" image="42556"][/kc_column][/kc_row]